ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学内発行雑誌
  2. The Showa University journal of medical sciences
  3. Vol.29(2017)
  4. No.2

Effect of Cardiac Rehabilitation in Preventing Implantable Cardioverter Defibrillator Therapy in Patients with Reduced Left Ventricular Ejection Fraction

https://showa.repo.nii.ac.jp/records/513
https://showa.repo.nii.ac.jp/records/513
b69c870b-89f1-4874-9857-066a769ff8e7
名前 / ファイル ライセンス アクション
S29_119.pdf S29_119.pdf (295.9 kB)
Item type 学内発行雑誌 / Departmental Bulletin Paper(1)
公開日 2017-12-07
タイトル
タイトル Effect of Cardiac Rehabilitation in Preventing Implantable Cardioverter Defibrillator Therapy in Patients with Reduced Left Ventricular Ejection Fraction
言語 en
言語
言語 eng
資源タイプ
資源タイプ departmental bulletin paper
著者 OGAWA, Ko

× OGAWA, Ko

OGAWA, Ko

Search repository
KAWAMURA, Mitsuharu

× KAWAMURA, Mitsuharu

KAWAMURA, Mitsuharu

Search repository
KOBA, Shinji

× KOBA, Shinji

KOBA, Shinji

Search repository
MUNETSUGU, Yumi

× MUNETSUGU, Yumi

MUNETSUGU, Yumi

Search repository
NAKAMURA, Yuya

× NAKAMURA, Yuya

NAKAMURA, Yuya

Search repository
OCHI, Akinori

× OCHI, Akinori

OCHI, Akinori

Search repository
INOKUCHI, Koichiro

× INOKUCHI, Koichiro

INOKUCHI, Koichiro

Search repository
YOKOTA, Yuya

× YOKOTA, Yuya

YOKOTA, Yuya

Search repository
ONUKI, Tatsuya

× ONUKI, Tatsuya

ONUKI, Tatsuya

Search repository
TSUNODA, Fumiyoshi

× TSUNODA, Fumiyoshi

TSUNODA, Fumiyoshi

Search repository
SHOJI, Makoto

× SHOJI, Makoto

SHOJI, Makoto

Search repository
WATANABE, Norikazu

× WATANABE, Norikazu

WATANABE, Norikazu

Search repository
KOBAYASHI, Youichi

× KOBAYASHI, Youichi

KOBAYASHI, Youichi

Search repository
書誌情報 The Showa University journal of medical sciences

巻 29, 号 2, p. 119-129, 発行日 2017-06
抄録
内容記述タイプ Abstract
内容記述 In patients with implantable cardioverter defibrillators(ICD)or cardiac resynchronization therapy defibrillators(CRT-D), appropriate and inappropriate shocks lead to a higher risk of mortality. Cardiac rehabilitation(CR)is an established therapy for patients with ischemic heart disease and/or congestive heart failure. However, it is unclear whether CR could reduce the need for device therapies. The purpose of the present study was to investigate whether CR reduces device therapies and mortality in patients with severe cardiac dysfunction and ICD or CRT-D. Of the 390 patients who were implanted with an ICD or CRT-D between 1998 and 2015, 222(178 men, 44 women)with a low ejection fraction(EF; <45%)were investigated in this present study. The study cohort was divided into two groups, the CR group(n=70)and the non-CR group (n=152), and baseline clinical characteristics of the two groups were compared. Furthermore, the number of all device therapies, appropriate therapies, inappropriate therapies, and mortality for 1 year after ICD or CRT-D implantation were compared. There were no significant differences in baseline characteristics between the CR and non-CR groups(e.g. age 68.5 vs 66.2 years[P=0.16]; EF 27.9% vs 29.7%[P=0.14]). Kaplan-Meier analysis revealed that all device therapy events and inappropriate therapy events were lower in the CR than non-CR group(P=0.01 and P=0.03, respectively). Appropriate therapy events and mortality did not differ significantly between the two groups(5.7% vs 13.1%[P=0.09]and 11.4% vs 17.0%[P=0.28], respectively). CR may have beneficial effects in preventing therapy events, especially inappropriate therapy, in patients with an ICD or CRT-D.
DOI
関連タイプ isIdenticalTo
関連識別子 10.15369/sujms.29.119
出版者
出版者 Showa University Society
ISSN
収録物識別子タイプ ISSN
収録物識別子 0915-6380
出版タイプ
出版タイプ VoR
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 12:44:44.404626
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3