ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学内発行雑誌
  2. The Showa University journal of medical sciences
  3. Vol.33(2021)
  4. No.2

A comparative study of asthma with airflow limitation and asthma-COPD overlap using the forced oscillation technique

https://showa.repo.nii.ac.jp/records/3809
https://showa.repo.nii.ac.jp/records/3809
578815dc-1344-440c-91b2-462f8cc3e76d
名前 / ファイル ライセンス アクション
S33_25.pdf S33_25.pdf (337.6 kB)
Item type 学内発行雑誌 / Departmental Bulletin Paper(1)
公開日 2021-07-28
タイトル
タイトル A comparative study of asthma with airflow limitation and asthma-COPD overlap using the forced oscillation technique
言語
言語 eng
資源タイプ
資源タイプ departmental bulletin paper
著者 SATO, Hiroki

× SATO, Hiroki

SATO, Hiroki

Search repository
TANAKA, Akihiko

× TANAKA, Akihiko

TANAKA, Akihiko

Search repository
HIRAI, Kuniaki

× HIRAI, Kuniaki

HIRAI, Kuniaki

Search repository
EBATO, Takaya

× EBATO, Takaya

EBATO, Takaya

Search repository
INOUE, Hideki

× INOUE, Hideki

INOUE, Hideki

Search repository
HOMMA, Tetsuya

× HOMMA, Tetsuya

HOMMA, Tetsuya

Search repository
OHTA, Shin

× OHTA, Shin

OHTA, Shin

Search repository
SUZUKI, Shintaro

× SUZUKI, Shintaro

SUZUKI, Shintaro

Search repository
SAGARA, Hironori

× SAGARA, Hironori

SAGARA, Hironori

Search repository
書誌情報 The Showa University journal of medical sciences

巻 33, 号 2, p. 25-33, 発行日 2021-06
抄録
内容記述タイプ Abstract
内容記述 The forced oscillation technique(FOT), which requires breathing without forced action, is a useful tool that can measure respiratory impedance. We investigated the physiological differences between asthma with smoking-unrelated airflow limitation and asthma-chronic obstructive pulmonary disease(COPD)overlap(ACO)using the FOT. Among 275 patients with asthma who presented at the Showa University Hospital from April 2018 through March 2019, 211 were enrolled and assigned into the asthma(BA), asthma with airflow limitation(AL), or ACO groups. Respiratory impedance measured using the FOT were compared among the groups. There were no significant differences in spirometry data between the AL and the ACO group. The AL group had higher respiratory resistance at 5Hz(R5), 20Hz(R20), and reactance at 5Hz than the ACO group, but there was no significant difference in subtracting R20 from R5(R5-R20). R5 and R20 were similar between the ACO and the BA groups, but R5-R20, resonant frequency(Fres), and low-frequency reactance area were significantly higher in the ACO group than the BA group. Fres yielded the highest area under the curve(AUC)to identify airflow limitation, and R20 yielded the highest AUC to identify the ACO group among patients with airflow limitation. An analysis using the cut off value to identify airflow limitation and ACO detected 33 patients as having ACO, 17 of whom were diagnosed with ACO. R5 and R20 measured by FOT are higher in AL than in ACO despite no difference in spirometry data, and are not significantly different between BA and ACO. Therefore, FOT aids our understanding of the physiological characteristics and provides clues for the treatment in asthmatics with airflow limitation.
DOI
関連識別子 10.15369/sujms.33.25
出版者
出版者 Showa University Society
ISSN
収録物識別子 2185-0968
著者版フラグ
出版タイプ VoR
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 11:51:56.601674
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3