{"created":"2023-05-15T11:21:31.566327+00:00","id":190,"links":{},"metadata":{"_buckets":{"deposit":"62c922c6-92c6-425a-8109-7945216bb40c"},"_deposit":{"created_by":1,"id":"190","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"190"},"status":"published"},"_oai":{"id":"oai:showa.repo.nii.ac.jp:00000190","sets":["1:6:19:22"]},"author_link":["918","915","916","917"],"item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2016-06"},"bibliographicIssueNumber":"3","bibliographicPageEnd":"360","bibliographicPageStart":"351","bibliographicVolumeNumber":"76","bibliographic_titles":[{"bibliographic_title":"昭和学士会雑誌"}]}]},"item_10002_description_6":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"超高齢社会化が急速に進行している現在,骨粗鬆症による橈骨遠位端骨折も増加している.近年,同骨折に対して掌側ロッキングプレート(以下,VLP)による固定が行われるようになった.骨折部を強固に固定するには,橈骨軟骨下骨をスクリューで支持する必要があるが,遠位1列の穴のみの固定では,骨粗鬆症により骨質が脆弱化していたり,骨の粉砕が強い場合に,十分な固定力が得られない.Orbayらは,VLPの遠位2列の穴から固定したスクリューで,関節面の2か所を支える遠位2列軟骨下骨支持固定(double-tiered subchondral support:DSS法) を提案し,一定角度で固定するプレート (dorsal volar radius(DVR)anatomic palte:Biomet社製) を開発した.その後,固定角度可変機構を有したプレート (固定角可変プレートpolyaxial locking plate:PLP) が開発され,骨折型,骨形状の違いに関わらず適応しやすくなった.われわれはこれまで,PLPであるAPTUS2.5 (Medartis社製) を用いたDSS法の臨床における良好な治療成績を報告してきた.しかし,現在,PLPを用いたDSS法の力学的強度評価に関する詳細な報告はない.そこで本研究では,人工骨と新鮮凍結屍体を用いて橈骨遠位端骨折モデルを作成し,力学的強度試験を行い,DSS法の有用性を検討した.Osadaらの報告に準じ,人工骨SYNBONEで,AO分類A型の擬似骨折を作り,APTUS2.5を用いて1.遠位1列目の穴を4本のスクリューで固定したモデル (0群:遠位2列目無固定),2.遠位2列目の穴を1列目と平行にスクリューで1本,2本,3本固定したモデル (P群),および,3.遠位2列目の穴に背側関節面から15度の角度で打ち上げて,スクリューを1本,2本,3本固定したモデル (D群) の3群の骨折モデルを作成した.これらのモデルに対し,橈骨遠位掌側から荷重負荷し1)橈骨軸方向静特性試験,2)橈骨軸方向繰返し荷重特性試験(1,000回,2,000回,3,000回),3)曲げ方向静特性負荷試験,4)曲げ方向繰り返し荷重試験 (3,000回) を行った.さらに,新鮮凍結屍体を用いて5)AO分類C-2型の骨折モデルを作成し,遠位1列目の穴のみをスクリュー固定したnonDSS群 (NDS群) と,遠位1列目の穴の固定に加え,2列目の穴に背側関節面に15度の角度で打ち上げて,スクリューを2本固定したDSS群(DS群)との間で,静荷重負荷試験による力学的強度の比較検討を行った.1)と2)の軸方向の試験において,剛性とモーメントは,全ての固定群間に有意差はなかった.3)と4)の曲げ方向の試験において,曲げ剛性と曲げモーメントは,遠位2列目の穴を固定したスクリュー本数の増加とともに若干の増加傾向をみたが,有意差はなかった.全ての骨折モデルにおいて,対照のMonoaxial locking plate (以下MLP) 固定とほぼ同様の力学的強度を認め,ロッキング機構のゆるみ,破損を認めなかった.5)破断強度試験におけるDS群の降伏点の平均値は490Nで,NDS群の降伏点の平均値の360Nに比べて有意に高値であった.人工骨では,APTUS2.5の力学的強度はMLPと同等であり,2列目の穴を固定したスクリューの本数や角度の違いでは,固定力に有意差は認めなかった.新鮮凍結屍体では,DS群の力学的強度がNDS群よりも高く.DSS法の有用性が認められた.\n","subitem_description_type":"Abstract"}]},"item_10002_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"昭和大学学士会"}]},"item_10002_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.14930/jshowaunivsoc.76.351"}}]},"item_10002_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"2187-719X"}]},"item_10002_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"中村, 裕介"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"川崎, 恵吉"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"稲垣, 克記"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"山越, 憲一"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-07-26"}],"displaytype":"detail","filename":"76_351.pdf","filesize":[{"value":"819.5 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"76_351.pdf","url":"https://showa.repo.nii.ac.jp/record/190/files/76_351.pdf"},"version_id":"a5c24893-f789-42d0-9e1e-96eedc093e00"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper"}]},"item_title":"橈骨遠位端骨折モデルにおける遠位2列軟骨下骨支持固定法の力学的強度 ","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"橈骨遠位端骨折モデルにおける遠位2列軟骨下骨支持固定法の力学的強度 "}]},"item_type_id":"10002","owner":"1","path":["22"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-05-15"},"publish_date":"2017-05-15","publish_status":"0","recid":"190","relation_version_is_last":true,"title":["橈骨遠位端骨折モデルにおける遠位2列軟骨下骨支持固定法の力学的強度 "],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T13:08:57.450206+00:00"}