WEKO3
アイテム
{"_buckets": {"deposit": "71f8617d-cedc-4c8e-8e08-87d7ec150ad0"}, "_deposit": {"created_by": 1, "id": "78", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "78"}, "status": "published"}, "_oai": {"id": "oai:showa.repo.nii.ac.jp:00000078", "sets": ["17"]}, "author_link": ["362", "361"], "item_10002_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2017-10", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "5", "bibliographicPageEnd": "558", "bibliographicPageStart": "551", "bibliographicVolumeNumber": "77", "bibliographic_titles": [{"bibliographic_title": "昭和学士会雑誌"}]}]}, "item_10002_description_6": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "ポリ塩化ビニル(polyvinyl chloride, PVC)は工業製品の素材として広く使用されている.これに可塑剤を添加することにより硬度を調節でき,用途に合わせた加工が可能になる.従来,可塑剤としてフタル酸ジ-2-エチルヘキシル(di(2-ethylhexyl)phthalate, DEHP)が主に添加されてきたが,DEHPはげっ歯類で精巣毒性等があることが報告され,PVC製医療機器は他の可塑剤への変更やPVC以外の原料への変更が求められた.その後,ヒトへの影響も複数報告されている.DEHP添加PVC製品はその機能性と低価格のため,現在でも医療機器として使用されているものが少なくない.ボタン型胃瘻チューブに接続されるチューブもその一つである.そこで胃瘻を介す経腸栄養剤投与時のDEHP溶出量を検討した.蒸留水をコントロールとして,4種類の経腸栄養剤(ラコールⓇ,エンシュア・リキッドⓇ,エンシュアⓇ・H,はぐくみⓇ)を室温下に胃瘻接続チューブを通過させたのち,採取溶液中のDEHP濃度を高速液体クロマトグラフィーを用いて測定した.胃瘻接続チューブはPVC製DEHP添加およびDEHP非添加の2種類を用い,各々以下の2つの実験を行った.実験1は,流入速度100ml/時で,溶液採取を1時間毎に2回行い,DEHP濃度を測定した.実験2は,流入速度約8ml/時で,溶液採取を1時間毎に6回,その後8,12時間目に採取し,DEHP濃度を測定した.実験1でコントロールと比較して,すべての経腸栄養剤でDEHP濃度の上昇を認めた.実験1での1時間注入量を実験2で12時間かけて注入した場合,すべての経腸栄養剤で実験1に比しDEHP濃度の有意の上昇を認めた.また,DEHPは脂肪への溶出がさらに容易となるといわれており,脂肪含量の違いによる溶出量の影響について検討した.結果,経腸栄養剤により脂肪含量に差を認めたが,DEHP溶出量と脂肪含量の関係に一定の傾向はみられなかった.そこで,同一製剤で脂肪含量の異なるエンシュアⓇ・Hとエンシュア・リキッドⓇを比較すると,脂肪含量の多いエンシュアⓇ・Hで溶出量が有意に高値を示していた.以上よりDEHP添加PVC製の胃瘻接続チューブを用いた場合,DEHP溶出量を少なくするためには注入速度を速めることが望ましく,とくに脂肪を多く含む栄養剤使用時にはその傾向が強い.ただ,脂肪含量が多い栄養剤は注入速度を速めると,下痢などの副作用を生じる危険性があり注意が必要である.一方,DEHP添加PVC製の胃瘻接続チューブを使用し,一般的な経腸栄養剤の投与を行うと,DEHP溶出量は容易に耐容一日摂取量を超える可能性がある.長期の栄養剤投与や小児の場合,健康への障害が発生する危険性があることからDEHPを含有しない栄養ルートの使用を推奨したい.", "subitem_description_type": "Abstract"}]}, "item_10002_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "昭和大学学士会"}]}, "item_10002_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.14930/jshowaunivsoc.77.551", "subitem_relation_type_select": "DOI"}}]}, "item_10002_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AA12635661", "subitem_source_identifier_type": "NCID"}]}, "item_10002_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "2187-719X", "subitem_source_identifier_type": "ISSN"}]}, "item_10002_text_26": {"attribute_name": "アイテムタイプ", "attribute_value_mlt": [{"subitem_text_value": "学内発行雑誌 / Departmental Bulletin Paper"}]}, "item_10002_text_27": {"attribute_name": "POS_INDEX", "attribute_value_mlt": [{"subitem_text_value": "学内発行雑誌/昭和学士会雑誌/77巻(2017)/5号"}]}, "item_10002_version_type_20": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "タナカ, 早恵"}], "nameIdentifiers": [{"nameIdentifier": "361", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "土岐, 彰"}], "nameIdentifiers": [{"nameIdentifier": "362", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-07-26"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "77_551.pdf", "filesize": [{"value": "596.6 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 596600.0, "url": {"label": "77_551.pdf", "url": "https://showa.repo.nii.ac.jp/record/78/files/77_551.pdf"}, "version_id": "5f0fd019-36db-46a5-9d55-7a5bb769014d"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "医療用ポリ塩化ビニル製品より溶出する可塑剤フタル酸ジ-2-エチルヘキシルの検討", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "医療用ポリ塩化ビニル製品より溶出する可塑剤フタル酸ジ-2-エチルヘキシルの検討"}]}, "item_type_id": "10002", "owner": "1", "path": ["17"], "permalink_uri": "https://showa.repo.nii.ac.jp/records/78", "pubdate": {"attribute_name": "公開日", "attribute_value": "2018-03-15"}, "publish_date": "2018-03-15", "publish_status": "0", "recid": "78", "relation": {}, "relation_version_is_last": true, "title": ["医療用ポリ塩化ビニル製品より溶出する可塑剤フタル酸ジ-2-エチルヘキシルの検討"], "weko_shared_id": 1}
医療用ポリ塩化ビニル製品より溶出する可塑剤フタル酸ジ-2-エチルヘキシルの検討
https://showa.repo.nii.ac.jp/records/78
https://showa.repo.nii.ac.jp/records/780c059d76-5621-4fe5-baef-0e52fbe8cc86
名前 / ファイル | ライセンス | アクション |
---|---|---|
77_551.pdf (596.6 kB)
|
|
Item type | 学内発行雑誌 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-03-15 | |||||
タイトル | ||||||
タイトル | 医療用ポリ塩化ビニル製品より溶出する可塑剤フタル酸ジ-2-エチルヘキシルの検討 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ | departmental bulletin paper | |||||
著者 |
タナカ, 早恵
× タナカ, 早恵× 土岐, 彰 |
|||||
書誌情報 |
昭和学士会雑誌 巻 77, 号 5, p. 551-558, 発行日 2017-10 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | ポリ塩化ビニル(polyvinyl chloride, PVC)は工業製品の素材として広く使用されている.これに可塑剤を添加することにより硬度を調節でき,用途に合わせた加工が可能になる.従来,可塑剤としてフタル酸ジ-2-エチルヘキシル(di(2-ethylhexyl)phthalate, DEHP)が主に添加されてきたが,DEHPはげっ歯類で精巣毒性等があることが報告され,PVC製医療機器は他の可塑剤への変更やPVC以外の原料への変更が求められた.その後,ヒトへの影響も複数報告されている.DEHP添加PVC製品はその機能性と低価格のため,現在でも医療機器として使用されているものが少なくない.ボタン型胃瘻チューブに接続されるチューブもその一つである.そこで胃瘻を介す経腸栄養剤投与時のDEHP溶出量を検討した.蒸留水をコントロールとして,4種類の経腸栄養剤(ラコールⓇ,エンシュア・リキッドⓇ,エンシュアⓇ・H,はぐくみⓇ)を室温下に胃瘻接続チューブを通過させたのち,採取溶液中のDEHP濃度を高速液体クロマトグラフィーを用いて測定した.胃瘻接続チューブはPVC製DEHP添加およびDEHP非添加の2種類を用い,各々以下の2つの実験を行った.実験1は,流入速度100ml/時で,溶液採取を1時間毎に2回行い,DEHP濃度を測定した.実験2は,流入速度約8ml/時で,溶液採取を1時間毎に6回,その後8,12時間目に採取し,DEHP濃度を測定した.実験1でコントロールと比較して,すべての経腸栄養剤でDEHP濃度の上昇を認めた.実験1での1時間注入量を実験2で12時間かけて注入した場合,すべての経腸栄養剤で実験1に比しDEHP濃度の有意の上昇を認めた.また,DEHPは脂肪への溶出がさらに容易となるといわれており,脂肪含量の違いによる溶出量の影響について検討した.結果,経腸栄養剤により脂肪含量に差を認めたが,DEHP溶出量と脂肪含量の関係に一定の傾向はみられなかった.そこで,同一製剤で脂肪含量の異なるエンシュアⓇ・Hとエンシュア・リキッドⓇを比較すると,脂肪含量の多いエンシュアⓇ・Hで溶出量が有意に高値を示していた.以上よりDEHP添加PVC製の胃瘻接続チューブを用いた場合,DEHP溶出量を少なくするためには注入速度を速めることが望ましく,とくに脂肪を多く含む栄養剤使用時にはその傾向が強い.ただ,脂肪含量が多い栄養剤は注入速度を速めると,下痢などの副作用を生じる危険性があり注意が必要である.一方,DEHP添加PVC製の胃瘻接続チューブを使用し,一般的な経腸栄養剤の投与を行うと,DEHP溶出量は容易に耐容一日摂取量を超える可能性がある.長期の栄養剤投与や小児の場合,健康への障害が発生する危険性があることからDEHPを含有しない栄養ルートの使用を推奨したい. | |||||
DOI | ||||||
関連識別子 | 10.14930/jshowaunivsoc.77.551 | |||||
出版者 | ||||||
出版者 | 昭和大学学士会 | |||||
ISSN | ||||||
収録物識別子 | 2187-719X | |||||
著者版フラグ | ||||||
出版タイプ | VoR |