Experimental Verification of Finite Element Analysis for a Thermoplastic Orthodontic Aligner

https://showa.repo.nii.ac.jp/records/613
https://showa.repo.nii.ac.jp/records/613
1215fef4-2346-405f-ab79-6ddc23b2b7c7
名前 / ファイル ライセンス アクション
S26_139.pdf S26_139.pdf (882.5 kB)
Item type 学内発行雑誌 / Departmental Bulletin Paper(1)
公開日 2016-12-21
タイトル
タイトル Experimental Verification of Finite Element Analysis for a Thermoplastic Orthodontic Aligner
言語
言語 eng
資源タイプ
資源タイプ departmental bulletin paper
著者 FUJITA, Yuko

× FUJITA, Yuko

FUJITA, Yuko

Search repository
KIMURA, Hitoshi

× KIMURA, Hitoshi

KIMURA, Hitoshi

Search repository
YANAGISAWA, Wakana

× YANAGISAWA, Wakana

YANAGISAWA, Wakana

Search repository
INOU, Norio

× INOU, Norio

INOU, Norio

Search repository
MAKI, Koutaro

× MAKI, Koutaro

MAKI, Koutaro

Search repository
書誌情報 The Showa University journal of medical sciences

巻 26, 号 2, p. 139-147, 発行日 2014-06
抄録
内容記述タイプ Abstract
内容記述 In recent years, good outcomes have been reported using transparent and removable orthodontic appliances known as aligners. However, unpredicted tooth movement that contradicted 3-dimensional image simulations was observed in some cases. These anomalies could relate to biomechanical factors ; in particular, the characteristics of mechanical loading applied to the periodontal ligament and the tooth crown by aligners remain unclear. This study examines the biomechanical characteristics of aligners by a new method as follows : 1) development of an experimental model using artificial teeth and plastic aligners ; 2) finite element (FE) modeling and analysis using computed tomography (CT) images of the experimental model ; and, 3) comparison among observations of this actual model and standard FE analysis results. Roots of two artificial teeth were covered by silicone material at 1.0 mm intervals for each coronal proximal surface and plastic clear aligners were manufactured based on another model in which the interval was reduced to 0.0 mm to simulate bodily movement. An FE analysis model of this 1.0 mm teeth interval was reconstructed from the CT images. A virtual aligner based on the FE model was also generated with a 0.0 mm interval. Changes in space between the root surface and silicone in both the actual and FE model were compared with the aligner fitted in the initial model. Identical tendencies of movement were observed in both experimental results - the artificial teeth and computational results of FE analysis. Our method using an experimental and computational approach proved useful to examine aligner characteristics ; the use of such a biomechanical approach could further our understanding of aligner treatments.
DOI
関連識別子 10.15369/sujms.26.139
出版者
出版者 Showa University Society
ISSN
収録物識別子 0915-6380
著者版フラグ
出版タイプ VoR
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 12:40:54.702051
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3