{"_buckets": {"deposit": "b2e8c639-d83d-4271-bbca-759805bc2228"}, "_deposit": {"created_by": 1, "id": "225", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "225"}, "status": "published"}, "_oai": {"id": "oai:showa.repo.nii.ac.jp:00000225", "sets": ["32"]}, "author_link": ["1106", "1102", "1109", "1105", "1103", "1101", "1107", "1108", "1104"], "item_10002_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2015-12", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "6", "bibliographicPageEnd": "646", "bibliographicPageStart": "641", "bibliographicVolumeNumber": "75", "bibliographic_titles": [{"bibliographic_title": "昭和学士会雑誌"}]}]}, "item_10002_description_6": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "強制オシレーション法は安静呼吸で測定できるため,小児において臨床応用が期待される呼吸機能検査法である.しかし,解析における安静呼吸抽出の指標として用いられるコヒーレンス0.7の妥当性が検証されたことはない.学童131名を対象にモストグラフの測定を安静呼吸10回以上で少なくとも3回以上行い,最も安定した呼吸の回を採用した.その後,コヒーレンス0.7,0.8,0.9をカットオフ値としてデータを抽出し結果を比較した.学童131名中基礎疾患や合併症のない95名の健常学童,平均年齢7.6歳±1.4を対象に解析を行った.コヒーレンスの異なる3群における,モストグラフの各測定値R5,R20,R5-R20,X5,Fres,ALXに関して,呼気,吸気,およびその平均値に有意差を認めなかった.また,解析対象の安静呼吸数が不安定な27例を抽出して同様の検討を行った.コヒーレンスの異なる3群における,モストグラフの各測定値R5,R20,R5-R20,X5,Fres,ALXに関して,呼気,吸気,およびその平均値に有意差を認めなかった.コヒーレンス0.7で抽出した安静呼吸は既に基準波形と十分に相関が高いため,コヒーレンスのカットオフ値をさらに上げても群間有意差を認めなかったと考えられた.また,コヒーレンスは呼吸波形の相関性を評価する呼吸の安定性の指標であるのに対し,FOT測定値である呼吸抵抗,リアクタンスはオシレーション波の反応から算出される.このため,相関の高い安静呼吸に基づいた測定値には差がなかったとも考えられた.モストグラフの測定において,コヒーレンスは0.7が妥当である.", "subitem_description_type": "Abstract"}]}, "item_10002_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "昭和大学学士会"}]}, "item_10002_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.14930/jshowaunivsoc.75.641", "subitem_relation_type_select": "DOI"}}]}, "item_10002_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AA12635661", "subitem_source_identifier_type": "NCID"}]}, "item_10002_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "2187-719X", "subitem_source_identifier_type": "ISSN"}]}, "item_10002_text_26": {"attribute_name": "アイテムタイプ", "attribute_value_mlt": [{"subitem_text_value": "学内発行雑誌 / Departmental Bulletin Paper"}]}, "item_10002_text_27": {"attribute_name": "POS_INDEX", "attribute_value_mlt": [{"subitem_text_value": "学内発行雑誌/昭和学士会雑誌/75巻(2015)/6号"}]}, "item_10002_version_type_20": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "矢川, 綾子"}], "nameIdentifiers": [{"nameIdentifier": "1101", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "今井, 孝成"}], "nameIdentifiers": [{"nameIdentifier": "1102", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "清水, 麻由"}], "nameIdentifiers": [{"nameIdentifier": "1103", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "宮沢, 篤生"}], "nameIdentifiers": [{"nameIdentifier": "1104", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "中村, 俊紀"}], "nameIdentifiers": [{"nameIdentifier": "1105", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "石川, 良子"}], "nameIdentifiers": [{"nameIdentifier": "1106", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "北條, 菜穂"}], "nameIdentifiers": [{"nameIdentifier": "1107", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "神谷, 太郎"}], "nameIdentifiers": [{"nameIdentifier": "1108", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "板橋, 家頭夫"}], "nameIdentifiers": [{"nameIdentifier": "1109", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-07-26"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "75_641.pdf", "filesize": [{"value": "598.3 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 598300.0, "url": {"label": "75_641.pdf", "url": "https://showa.repo.nii.ac.jp/record/225/files/75_641.pdf"}, "version_id": "6ad9e81a-b135-41d8-9d65-cb213cedf0e3"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "モストグラフ測定時のコヒーレンスに関する検証", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "モストグラフ測定時のコヒーレンスに関する検証"}, {"subitem_title": "THE EVALUATION OF COHERENCE VALUES TO MEASURE LUNG FUNCTION BY USING MOSTGRAPH", "subitem_title_language": "en"}]}, "item_type_id": "10002", "owner": "1", "path": ["32"], "permalink_uri": "https://showa.repo.nii.ac.jp/records/225", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-05"}, "publish_date": "2017-10-05", "publish_status": "0", "recid": "225", "relation": {}, "relation_version_is_last": true, "title": ["モストグラフ測定時のコヒーレンスに関する検証"], "weko_shared_id": -1}
モストグラフ測定時のコヒーレンスに関する検証
https://showa.repo.nii.ac.jp/records/225
https://showa.repo.nii.ac.jp/records/2257938eeae-410b-4a16-8cb7-c394c5247c0a
名前 / ファイル | ライセンス | アクション |
---|---|---|
75_641.pdf (598.3 kB)
|
|
Item type | 学内発行雑誌 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-05 | |||||
タイトル | ||||||
タイトル | モストグラフ測定時のコヒーレンスに関する検証 | |||||
タイトル | ||||||
タイトル | THE EVALUATION OF COHERENCE VALUES TO MEASURE LUNG FUNCTION BY USING MOSTGRAPH | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ | departmental bulletin paper | |||||
著者 |
矢川, 綾子
× 矢川, 綾子× 今井, 孝成× 清水, 麻由× 宮沢, 篤生× 中村, 俊紀× 石川, 良子× 北條, 菜穂× 神谷, 太郎× 板橋, 家頭夫 |
|||||
書誌情報 |
昭和学士会雑誌 巻 75, 号 6, p. 641-646, 発行日 2015-12 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 強制オシレーション法は安静呼吸で測定できるため,小児において臨床応用が期待される呼吸機能検査法である.しかし,解析における安静呼吸抽出の指標として用いられるコヒーレンス0.7の妥当性が検証されたことはない.学童131名を対象にモストグラフの測定を安静呼吸10回以上で少なくとも3回以上行い,最も安定した呼吸の回を採用した.その後,コヒーレンス0.7,0.8,0.9をカットオフ値としてデータを抽出し結果を比較した.学童131名中基礎疾患や合併症のない95名の健常学童,平均年齢7.6歳±1.4を対象に解析を行った.コヒーレンスの異なる3群における,モストグラフの各測定値R5,R20,R5-R20,X5,Fres,ALXに関して,呼気,吸気,およびその平均値に有意差を認めなかった.また,解析対象の安静呼吸数が不安定な27例を抽出して同様の検討を行った.コヒーレンスの異なる3群における,モストグラフの各測定値R5,R20,R5-R20,X5,Fres,ALXに関して,呼気,吸気,およびその平均値に有意差を認めなかった.コヒーレンス0.7で抽出した安静呼吸は既に基準波形と十分に相関が高いため,コヒーレンスのカットオフ値をさらに上げても群間有意差を認めなかったと考えられた.また,コヒーレンスは呼吸波形の相関性を評価する呼吸の安定性の指標であるのに対し,FOT測定値である呼吸抵抗,リアクタンスはオシレーション波の反応から算出される.このため,相関の高い安静呼吸に基づいた測定値には差がなかったとも考えられた.モストグラフの測定において,コヒーレンスは0.7が妥当である. | |||||
DOI | ||||||
関連識別子 | 10.14930/jshowaunivsoc.75.641 | |||||
出版者 | ||||||
出版者 | 昭和大学学士会 | |||||
ISSN | ||||||
収録物識別子 | 2187-719X | |||||
著者版フラグ | ||||||
出版タイプ | VoR |