The Usefulness of C-arm CBCT-guided Abscess Drainage with A Flat-panel Detector

https://showa.repo.nii.ac.jp/records/693
https://showa.repo.nii.ac.jp/records/693
57272bf2-9cc5-4243-a32d-fd83d7595e18
名前 / ファイル ライセンス アクション
S24_59.pdf S24_59.pdf (390.3 kB)
Item type 学内発行雑誌 / Departmental Bulletin Paper(1)
公開日 2016-11-28
タイトル
タイトル The Usefulness of C-arm CBCT-guided Abscess Drainage with A Flat-panel Detector
言語
言語 eng
資源タイプ
資源タイプ departmental bulletin paper
著者 IKEDA, Shinya

× IKEDA, Shinya

IKEDA, Shinya

Search repository
SEINO, Noritaka

× SEINO, Noritaka

SEINO, Noritaka

Search repository
HASHIZUME, Takashi

× HASHIZUME, Takashi

HASHIZUME, Takashi

Search repository
SAI, Syouei

× SAI, Syouei

SAI, Syouei

Search repository
GOKAN, Takehiko

× GOKAN, Takehiko

GOKAN, Takehiko

Search repository
書誌情報 The Showa University journal of medical sciences

巻 24, 号 1, p. 59-67, 発行日 2012-03
抄録
内容記述タイプ Abstract
内容記述 Herein we report our experience with a C-arm cone beam computed tomography (CBCT)-guided abscess drainage procedure. We retrospectively examined the medical records and imaging results of patients whose abscesses were drained between 2005 and 2010 employing this system. We analyzed the technical success rate and incidence of procedure-related complications. Percutaneous abscess drainage using C-arm CBCT was performed using a flat-panel detector digital subtraction angiography (DSA) system on 104 lesions in 97 patients (55 men, 42 women) with a mean age of 64.7 (30-88) years. The drainage procedure was performed twice in 6 patients and 3 times in 2 patients, and 6 patients received 2 or more punctures at the same time. The technical success rate with this procedure was 98.1% (102 of 104 lesions). Placement of the drainage tube was abandoned in 2 patients due to difficulty in inserting a wire into the abscess cavity in 1 case and difficulty looping the wire in the other. The incidence of procedure-related complications was 3.85% (4 of 104 lesions). Our retrospective study and review of the relevant literature revealed that the C-arm CBCT-guided abscess drainage procedure examined was generally safe for patient use, showed a high technical success rate and low incidence of procedure-related complications, and was useful for abscesses that were inaccessible using other instruments. Although C-arm CBCT has limited contrast resolution, this disadvantage is easily overcome by comparing images with those obtained using other modalities.
DOI
関連識別子 10.15369/sujms.24.59
出版者
出版者 Showa Medical Association and Showa University
ISSN
収録物識別子 0915-6380
出版タイプ
出版タイプ VoR
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 12:38:14.295502
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3